Hours of opening
Mon-Thurs 8.30am-12pm 2pm-5pm
Friday 8.30am-12pm 2pm-4.30pm
Sat (1st and 3rd only) 9.30am-12pm
Sunday Closed
Bank Holidays Closed |
Dimension For G Series
| Ref | External Dimensions | Internal Dimensions | Volume | Batts | Weight | Stand Height |
| H x W x D | H x W x D | size | ||||
| G2 | 74 x 58.5 x
60 29" x 23" x 24" |
42 x 39.5 x 39.5 16.5" x 15.5" x 15.5" |
62l ltr 2.2 Cu.ft |
33x33 13"x13" |
70Kg 154lbs |
60 24" |
| G4 |
87 x 70 x 65 34" x 27.5" x 25.5" |
49.5 x 485 x 47 19.5" x 19" x 18.5" |
118 ltr 4.2 Cu.ft |
43x43 17"x17" |
105Kg 231lbs |
60 24" |
| G7 | 113 x 74 x 65 44.5" x 29" x 25.5" |
77.5 x 495 x 47 30.5 x 19.5 x 18.5 |
187 ltr 6.7 Cu.ft |
43 x 43 17"x17" |
133Kg 292lbs |
33 14" |
Dimensions For the K and J Series
| Ref | External Dimensions | Internal Dimensions | Volume | Batts | Weight | Stand Height |
| H x W x D | H x W x D | size | ||||
| K5 |
81cm x 79cm x 72cm 32" x 31" x 28.5" |
56cm x 51cm x 53cm 22 "x 202 x 21" |
151ltr 5¼ Cu.ft |
51 x 43 20" x 17" |
200 Kg 440 lbs |
61 24" |
| K8 |
109cm x 79cm x 72cm 43" x 31" x 28.5" |
83cm x 51cm x 53cm 33" x 20" x 21" |
224 ltr 8 Cu.ft |
51 x 43 20" x 17" |
280 Kg 617 lbs |
46 18" |
| J9 |
102cm x 80.5cm x 72cm 40" x31¾" x 28¼" |
81cm x 56cm x 56cm 32" x 22" x 22" |
254 ltr 9 Cu.ft |
49 x 25 19" x 10" |
160 Kg 353 lbs |
60 24" |
| J12 |
102cm x 91cm x 90cm 40" x 36" x 35.5" |
79cm x 66cm x 66cm 31" x 26" x 26" |
343 ltr 12.5 Cu.ft |
61 x 30 24" x 12" |
199 Kg 439 lbs |
60 24" |
| J18 |
110cm x 97cm x 97cm 43" x 38" x 38" |
86cm x 74cm x 79cm 34" x 29" x 31" |
500 ltr 17.5 Cu.ft |
66 x 35 26" x 14" |
232 Kg 512 lbs |
60 24" |
| J27 |
168cm x 105cm x 102cm 66" x 41.5" x 40" |
132cm x 74cm x 79cm 52" x 29" x 31" |
750 ltr 26.5 Cu.ft |
66 x 35 26" x 14" |
360 Kg 792 lbs |
45 18" |
|
1.Ventilitationhood (± 38CM 15") should be added to height. 2. Door adds 10CM-4" (8cm - 3" G series). This can be removed for installation, if required. 3.These sizes are for half bats. IE two required per level - (except K series) main body weight (I.E without stand). Stand is a separate unit. (Except J27 - This has removable legs.)
Right hanging, if required.
|
Prices for the Laser Gas Kilns
|
Model |
Price
in £ |
Model |
Prices in £ |
Model |
Price in £ |
Model |
Price in £ |
|
G2P |
£1,240.00 |
P1/2 |
£6,056.00 |
K5P |
£2,315.00 |
J9p |
£2,560.00 |
|
G2N |
£1,290.00 |
P2/2 |
£7,896.00 |
K5nT |
£2,470.00 |
J9n |
£2,618.00 |
|
G4P |
£1,594.00 |
P4/2 |
£10,038.00 |
K8 |
£3,275.00 |
J9nT |
£2,70000 |
|
G4N |
£1,680.00 |
|
K8nT |
£3,646.00 |
J12p |
£3800.00 |
|
|
G7P |
£1,974.00 |
J12n |
|
||||
|
G7N |
£2,050.00 |
J12nT |
£4,170.00. |
||||
|
J18p |
£4,800.00 |
||||||
|
J18n |
POA |
||||||
|
J18nT |
£5,176.00 |
||||||
|
J27p |
£6,495.00 |
||||||
|
J27nT |
£6,870.00 |
||||||
|
Furniture Sets
|
G2.........£65.00 G4.........£109.00 G7.........£148.00 K5.........£115.00 K8.........£155.00 J9..........£224.00 J12........£328.00 J18........£376.00 J27........£512.00 P ......... POA |
Accessories
|
Battery digital pyrometer ......................... Mains digital pyrometer............................ Thermocouple........................................ Oxygen analyser..................................... Ventilation hood (G series/J9/K5)............... Ventilation hood (J series/K8).................... Vent. pipe (flexible)................................. Vent pipe (rigid)...................................... Rain Cap................................................ Roof seal kit for vent pipe......................... Kiln stand (included with J&K Series)........... Castor set (locking)................................. Castor set (locking-K5/J12 and larger).........
Digital pyrometer with set-able cut off/alarm
College safety system (room CO and GAS monitor/alarm and cut off unit)
Solenoid shut off-valve (required either two above units) |
£100.00 £110.00 £70.00 POA £123.00 £185.00 £21.00/Mtr POA £38.00 £72.00 £115.00 £45.00 £70.00
£180.00
£275.00
£60.00
|
| Supplied as
standard with all kilns: Burner system including flame failure protection,
ignition system, gas pressure regulator, Instruction book, bungs dampers. Propane or bottle gas kilns (designated P-e.g G&P) gas input gauge, manual change-over system for two gas bottles with gas contents gauge (except G2p model) On natural gas or mains gas kilns ) designated N e.g G&n): gas input gauge or flowmeter. On J&K series kilns: kiln stand. On Turbo kilns (designated T -e.g J12nT): Forced air burner system. Turbo kilns may be used with any type of gas. |
All Prices are exclusive of
Delivery charge and VAT.
Prices subject to change
and are shown in UK pounds £
Medcol (Cornwall) Ltd
17 Woods Browning Ind. Est
Bodmin, Cornwall.
PL31 1DQ
Tel: 01208 72260 Fax 01208 78012
Email Sales medcolcwll@aol.com